FullCure 720


FullCure 720

FullCure 720 is a translucent amber acrylic-based photopolymer material. FullCure 720 is suitable for a wide range of rigid models, particularly where visibility of liquid flow or internal details is needed. This material is certified for medical use and fully sterilizable. Ideal for creating models for guided surgery

Mechanical Properties Test Method English Metric
Tensile Strength ASTM D638-03 7,250-9,450 psi 50-65 MPa
Tensile Modulus ASTM D638-04 290,000-435,000 psi 2,000-3,000 MPa
Tensile Elongation ASTM D638-05 15-25% 15-25%
Flexural Strength ASTM D790-03 12,000-16,000 psi 80-110 MPa
Flexural Modulus ASTM D790-04 390,000-480,000 psi 2,700-3,300 MPa
IZOD Impact, notched ASTM D256-06 0.375-0.562 ft-lb/in 20-30 J/m
Thermal Properties Test Method English Metric
HDT @ 0.45 MPa ASTM D648-06 113-122°F 45-50°C
HDT @ 1.82 MPa ASTM D648-07 113-122°F 45-50°C
Glass Transition Temp. (Tg) DMA E» 118-122°F 48-50°C
Other Test Method Value Available Colors
Shore Hardness (D) Scale D 83-86
Translucent Amber
Rockwell Hardness Scale M 73-76
Polymerized density ATSM D792 1.18-1.19 g/cm3
Ash content USP281 0.01-0.02 %
Water absorption, % D570-98 24hr 1.5-2.2 %
Medical Approvals      
Cytotoxicity      
Irritation      
Sensitization      
USP Class VI      
Genotoxicity, Ames test